6 Communication settings and guide of HMI connecting with controller
Q06H series CPU port communication
1.HMI Default1152008odd1
2. PLC Station No.0one HMI communicate with one PLC
3.If baud rate is wrongHMI will set the baud rate of PLC the same as HMI.
RS232 communication
QJ71C24 module communication: choose Mitsubishi Q_QnA (Link Port) or Mitsubishi
Melsec Q drive
Differences:
1. Mitsubishi Q_QnA (Link Port) protocol advantage is communication speed, disadvantages does
not support module RS232 communications;
2. Mitsubishi Melsec Q protocol advantages is that it support RS232 and RS485 communication
modules, disadvantage is that communication is slow.
HMI setting
Module default parameters: 9600, 8, odd, 1; station:0
RS232